Bending Test 1. Set the cable connector on the fixture. 2. Adjust the angle. 3. Hang the standard weight on the cable. 4. Plugin the cable. 5. Set the time and speed. 6. Start to test. Pulling Force Test 1. Set the receptacle on the testing machine. 2. Plug the cable in the receptacle. 3. Hang a relative standard weight on it. 4. Test the cable by the condition of the test. 5. Test the front side, reverse side, and two side faces in the same situation. 6. Check the conduction of the cable. TDR Test (Time Domain Reflectometry) 1. Set the parameter in the computer. 2. Connect the testing cable to the relative position. 3. Start to test the cable. 4. Export the data and eye pattern and check. Insertion & Extraction Force Test 1. Put the receptacle and the connector on the machine. 2. Adjust the fixture. 3. Set the frequency, time and speed. 4. Start to test. 5. Export the data and check. High-Temperature Cycling Test & High-Temperature Life Test 1. Set up the temperature and time. 2. Start to test. 3. Put the cable under the room temperature. 4. Check the exterior. RoHS Material Test 1. Put the material into the machine. 2. Set up the parameter and the test item. 3. Start to test. 4. We can get the analysis from the computer. RoHS Chemical Material Test 1. Put all the things that the test needs on the table. 2. Use the ultrasound to dissolve the chemical solvent. 3. Use the dropper to draw the chemical material. 4. Set up the value in the computer. 5. Drop the chemical material into the machine then set the temperature and time. 6. Start to test. 7. We can know that it passes or not by the waveform. Salt Spray Test 1. Set the concentration of the saltwater, temperature and time. 2. Put the cable into the machine and close the lid. 3. Start to test. 4. Take out the cable. 5. Check the exterior. If you want to know more information, please follow us to see more.